Andrew ATC300-1000 - Andrew - Launch 3 Direct
Andrew ATC300-1000 - Andrew - Launch 3 Direct

Andrew ATC300-1000

Controller, Andrew, 6 Outputs Teletilt Rack Mount RET Controller

Manages RET antennas and AISG TMAs remotely over a network Provides one AISG and six SMB ports on one controller Supports up to 32 antenna line devices depending on cable configuration and power consumption Accepts either 48 Vdc or +24 Vdc Complimentary ANMS Site Manager software available For indoor use only






























































































































































































General Specifications  
Includes   Control unit   |   Ethernet crossover cable   |   RS 232 serial cable   |   Site configuration worksheet
Rack Type   EIA 19 in
Rack Units   1
   

Electrical Specifications  
Protocol   AISG 1.0   |   AISG 1.1   |   AISG 2.0
Interface Protocol Signal   Data   |   dc
Input Voltage   -48 Vdc   |   +24 Vdc
Output Current at Voltage, continuous   1.6 A @ 24 V
Output Current at Voltage, maximum   2.0 A @ 24 V
Output Voltage, typical   24 V
Power Consumption, idle state   5 W
Power Consumption, maximum   70.0 W
Electromagnetic Compatibility (EMC)   CFR 47 Part 15, Subpart B, Class A   |   EN 55022   |   EN 55024   |   EN 61000-4-2   |   EN 61000-4-3   |   EN 61000-4-4   |   EN 61000-4-5   |   EN 61000-4-6   |   EN 61000-4-8   |   ETS 300 386 V1.3.2 2003   |   ICES-003 Issue 4 CAN/CSA-CEI/IEC CISPR 22:02
EU Certification   CB   |   CE
   

Mechanical Specifications  
AISG Alarm Relays   Major   |   Minor
AISG Input Connector   8-pin DIN Female
AISG Input Connector Quantity   1
Auxiliary Interface   Serial RS-232 DB9 Female
Color   Black
Material Type   Aluminum extrusion
Modem Interface  SMB Female
Modem Interface Quantity   6
Network Interface   Ethernet RJ45
Network Protocol   Internet Protocol
Remote Control Capability  HTTP   |   SNMPv2c
   

Environmental Specifications  
Climatic Sequence Test Method   IEC 60068-2-14
Cold Exposure Test Method   IEC 60068-2-1
Damp Heat Exposure Test Method   IEC 60068-2-30, Test Condition Db
Heat Exposure Test Method   IEC 60068-2-2
Operating Altitude   -100 to +3000 m
Operating Temperature   -20 °C to +55 °C (-4 °F to +131 °F)
Packaged Product Shock Test Method   ASTM D4169   |   GR-63-CORE, Section 4.1.1
Relative Humidity   5%–95%, non-condensing
   

Interface Port Drawing  
 Click on image below to enlarge.

   
   

Dimensions  
Width   482.6 mm   |   19.0 in
Depth   205.7 mm   |   8.1 in
Height   43.18 mm   |   1.70 in
Net Weight   1.6 kg   |   3.5 lb

Controller, Andrew, 6 Outputs Teletilt Rack Mount RET Controller

Manages RET antennas and AISG TMAs remotely over a network Provides one AISG and six SMB ports on one controller Supports up to 32 antenna line devices depending on cable configuration and power consumption Accepts either 48 Vdc or +24 Vdc Complimentary ANMS Site Manager software available For indoor use only






























































































































































































General Specifications  
Includes   Control unit   |   Ethernet crossover cable   |   RS 232 serial cable   |   Site configuration worksheet
Rack Type   EIA 19 in
Rack Units   1
   

Electrical Specifications  
Protocol   AISG 1.0   |   AISG 1.1   |   AISG 2.0
Interface Protocol Signal   Data   |   dc
Input Voltage   -48 Vdc   |   +24 Vdc
Output Current at Voltage, continuous   1.6 A @ 24 V
Output Current at Voltage, maximum   2.0 A @ 24 V
Output Voltage, typical   24 V
Power Consumption, idle state   5 W
Power Consumption, maximum   70.0 W
Electromagnetic Compatibility (EMC)   CFR 47 Part 15, Subpart B, Class A   |   EN 55022   |   EN 55024   |   EN 61000-4-2   |   EN 61000-4-3   |   EN 61000-4-4   |   EN 61000-4-5   |   EN 61000-4-6   |   EN 61000-4-8   |   ETS 300 386 V1.3.2 2003   |   ICES-003 Issue 4 CAN/CSA-CEI/IEC CISPR 22:02
EU Certification   CB   |   CE
   

Mechanical Specifications  
AISG Alarm Relays   Major   |   Minor
AISG Input Connector   8-pin DIN Female
AISG Input Connector Quantity   1
Auxiliary Interface   Serial RS-232 DB9 Female
Color   Black
Material Type   Aluminum extrusion
Modem Interface  SMB Female
Modem Interface Quantity   6
Network Interface   Ethernet RJ45
Network Protocol   Internet Protocol
Remote Control Capability  HTTP   |   SNMPv2c
   

Environmental Specifications  
Climatic Sequence Test Method   IEC 60068-2-14
Cold Exposure Test Method   IEC 60068-2-1
Damp Heat Exposure Test Method   IEC 60068-2-30, Test Condition Db
Heat Exposure Test Method   IEC 60068-2-2
Operating Altitude   -100 to +3000 m
Operating Temperature   -20 °C to +55 °C (-4 °F to +131 °F)
Packaged Product Shock Test Method   ASTM D4169   |   GR-63-CORE, Section 4.1.1
Relative Humidity   5%–95%, non-condensing
   

Interface Port Drawing  
 Click on image below to enlarge.

   
   

Dimensions  
Width   482.6 mm   |   19.0 in
Depth   205.7 mm   |   8.1 in
Height   43.18 mm   |   1.70 in
Net Weight   1.6 kg   |   3.5 lb